Abstract
A torque converter was tested for two turbine/pump rotational speed ratios, 0.065 and 0.800, and a laser velocimeter was used to measure three components of velocity within the pump. Shaft encoders were used to record the instantaneous pump angular position, which was correlated with the velocities. Average flow velocity profiles were obtained for the pump inlet, mid-, and exit planes. Large separation regions were seen in the mid- and exit planes of the pump for a speed ratio of 0.800. Strong counterclockwise secondary flows were observed in the midplane and strong clockwise secondary flows were seen in the exit plane of the pump for all conditions; vorticities were evaluated and are reported. Velocity data were also used to find the torque distribution. For both speed ratios the torque was approximately evenly distributed between the inlet and exit. Finally, slip factors were evaluated at the mid-and exit planes. At the midplane they were approximately the same as for conventional centrifugal pumps; however, at the exit plane the slip factors are larger than for centrifugal pumps.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.