Abstract
A simple and robust testing system based on a laser self-mixing grating interferometer (SMGI) is proposed to determine the sensitivity of accelerometers. Self-mixing grating interference occurs when the light emitted from a laser diode is incident onto a reflective grating at a fixed angle and the first-order diffracted light returns back into the laser cavity. Frequency ratio method and minimum point method that are officially used to calibrate accelerometers are modified to make it suitable to an SMGI testing system. In order to evaluate the performance of the proposed method, the sensitivity of a commercial microelectromechanical system accelerometer was tested at different vibration frequency. The obtained results show good agreement with the sensitivity given by the manufacturer's specification. Given its stability, simplicity, and efficiency, the proposed system has the potential to be adopted as an alternative method to test accelerometers for industrial applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.