Abstract
We present the results of a non-destructive measuring method allowing us to characterize the evolution of solder joints during thermal cycling ageing tests. The method uses a high resolution optical probe to detect selectively pure Joule and Peltier thermal responses of the solder joint subject to a given current pulse. The results show the Peltier and Joule responses to be good indicators for the evaluation of the age and the degradation of solder joints.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.