Abstract

The copper vapor density after the occurrence of a magnetically stabilized high-current vacuum arc was measured by the laser absorption method. Measurements were performed in a vacuum triggered gap with oxygen-free, axial magnetic field (AMF) Cu electrodes (40-mm-diameter cathode and 60-mm-diameter anode), separated by a gap of 30 mm. The arc current was a sinusoidal wave having a half-period of approximately 10 ms and a peak value ranging from 3 to 10 kA. The arc was stabilized by a magnetic field produced by the AMF electrodes. The copper vapor density at current zero increased with peak arc current and did not depend on the current zero slope. After current zero, the copper vapor density decayed with a time constant of approximately 400 /spl mu/s. These results can be explained by a model based on vapor expansion from cathode spot craters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.