Abstract

Introduction: The costs of flexible ureterorenoscopes (fURS) and their repair oblige the surgeon to know the proper handling of instruments. There is a lack of evidence in the literature about the distance that the laser fiber should have once out from the scope to avoid instrumental damages. We are introducing the “safety distance” concept to preserve the fURS scope from laser energy injuries. Materials and Methods: We performed an in vitro observational study. Seven fURS were tested. The distance from the laser fiber tip and the fURS camera was measured at the first appearance on the endoscopic screen and when the fiber was reaching one-fourth of the screen. Next, to evaluate the impact of the holmium laser bubble according to the different fiber distances, an assessment of the size and shape of the bubble created at the tip of the fiber with the laser activated was done recording the images with an high-speed camera. Different laser setting were used to simulate dusting, fragmentation, and tissue ablation. The laser was activated in saline solution with anything in front, with a phantom of a synthetic soft and hard stone and with a sample of pork kidney. Than maintaining the same energy and frequency, only the pulse length was changed and the diameter of the bubble measured. Results: The first appearance on the screen of the laser tip is different in different scopes. When the laser fiber is out 3 mm from the scope, the energy bubble generated by the holmium laser never hit the scope's tip. In all the scopes, we observed that when the laser fiber was at one-fourth of the screen, it was already out from the scope at least 3 mm. At the same energy and frequency, bubbles generated with long pulse are smaller than those generated with short pulse. Conclusion: Even if there is a big limitation of this study due to the impossibility to measure and to evaluate the damage of the fURS tip surface, we observed that when the laser fiber tip reach one-fourth of the screen, the bubble generated by the laser activation is never rebounding on the camera of the scope. We have called this position the “safety distance.” In difficult cases, if we need to see barely the fiber, we suggest to use long pulse duration and low energy. No competing financial interests exist. Runtime of video: 4 mins 42 secs This video was presented at the World Congress of Endourology, 2016, in Capetown, South Africa, and won Best Video Award of the WCE 2016.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.