Abstract

The ablated depth and volume per laser pulse from an aluminum target were measured for pulse durations that ranged from 80 fs to 270 ps at an average fluence of approximately 100 J/cm2 and a wavelength of 0.8 microm. The ablated volume showed a flat maximum for subpicosecond pulses and a minimum for approximately 6 ps. The crater diameters were rather constant up to pulse durations of approximately 6 ps and increased for larger pulse durations. As a result, the ablated depth also showed a plateau for subpicosecond pulses but decreased monotonically with pulse duration. A physical interpretation of these results and their consequences for laser applications are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.