Abstract

Pulmonary artery size is a crucial determinant of hemodynamic energy loss in total cavopulmonary connections. We investigated the effect of aortic arch reconstruction on left pulmonary artery size based on their anatomic proximity. Thirty-two patients undergoing the Fontan operation, 16 with hypoplastic left heart syndrome and 16 with non-hypoplastic left heart syndrome, were selected from the multicenter Fontan magnetic resonance imaging database at the Georgia Institute of Technology. The 16 datasets were consecutive with full anatomic reconstructions of the total cavopulmonary connection and aortic arch with no artifacts. The size of the aorta along the transverse arch and left pulmonary artery size in the region below the aortic arch was quantified by using a previously validated skeletonization technique. The transverse aortic and left pulmonary artery measurements (median, maximum, and minimum, respectively) for non-hypoplastic left heart syndrome were 2.2, 3.1, and 1.5 cm/m and 1.2, 1.6, and 0.2 cm/m, respectively, compared with 2.5, 4.1, and 2.0 cm/m and 0.9, 1.5, and 0.4 cm/m for patients with hypoplastic left heart syndrome. Thus the transverse aortic diameter of patients with hypoplastic left heart syndrome was, on average, 24% greater than that for patients with non-hypoplastic left heart syndrome (P < .05), whereas the left pulmonary artery diameter of patients with hypoplastic left heart syndrome was smaller than that of patients with non-hypoplastic left heart syndrome (P < .05). Regression analysis showed a significant negative correlation (P < .05) between aortic and left pulmonary artery diameters in both the hypoplastic left heart syndrome and non-hypoplastic left heart syndrome groups. However, when the study population was regrouped into reconstructed aorta and nonreconstructed aorta groups, the negative correlation was only significant for patients with reconstructed aortas, regardless of ventricular pathology (P < .02). Stage 1 aortic reconstruction procedures that result in a large aorta limit left pulmonary artery size in patients undergoing the Fontan operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.