Abstract

This study outlines a variant of three-dimensional OH planar laser-induced fluorescence and its application in characterising a single bluff body stabilised flame inside a 12 burner annular combustor. In this variant of the method a relatively large volume was scanned slowly in order to calculate the full three-dimensional Flame Surface Density (FSD) distribution. The method used a combination of two scanning directions to overcome bias errors associated with laser sheet positions close to the flame edges. The source of this bias error was confirmed numerically through a complimentary synthetic PLIF study, which was also used to refine the experimental setup. The bias error resulted in a reduction of FSD magnitude, although the method was still capable of capturing the flame structure. This was demonstrated by comparing the reconstructions from the two independent scan directions. Combining the data from both directions overcame the bias, and allowed flame asymmetry due to the confinement to be assessed. The FSD was used to determine the heat release rate of the flame with varying local azimuthal angle for different downstream regions. This highlighted the highly asymmetric structure, produced by the asymmetric confinement.Graphical abstract

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call