Abstract

BackgroundProsthetic mesh implants in hernia repair are frequently used based on the fact that lower recurrence rates are detected. However, an undesirable side effect is persistent foreign body reaction that drives adhesions and shrinkage among other things in the course of time. Thereby a variety of meshes have been created in an attempt to alleviate these side effects, and particular relating to shrinkage, the ideal mesh has not been developed. Large pore size is one of the properties to get better ingrowth of the implants but could also be a risk factor to shrinkage behavior. The aim of this preclinical study was to determine optimal pore size based on mesh integration and shrinkage in a hernia minipig model. MethodsTwenty female minipigs were each implanted at four abdominal retromuscular sites with meshes (designed and knitted specifically for this study) that had various weights and pore sizes, but similar weave. At 3 and 21 weeks post-operation, ten pigs each were euthanized. Mesh integration and shrinkage were evaluated through macroscopic observation, biomechanical testing and histopathological analysis. ResultsThe large pore meshes (6.1–6.6 mm2) showed significantly better integration than small pore (0.9–1.1 mm2) counterparts, by biomechanical testing and histological assessment. This was independent of mesh weight. The lightweight small pore mesh exhibited significantly more shrinkage than any of the other meshes, while the three-dimensional heavyweight large pore mesh exhibited the least shrinkage. Mesh shrinkage and elongation at 50 Newton (N) as one parameter of the implant structural stability appeared to be strongly interrelated. ConclusionTissue ingrowth of meshes depends on increasing pore size. Macroporous mesh design >1.5 mm diameter appears to be optimal in terms of mesh integration. Lightweight meshes with a large pore size on one hand and a lack of structural stability on the other hand drives mesh shrinkage. High stretchability (Elongation >50 N) induces higher shrinkage and therefore elongation at 50 N appears to be a new parameter to estimate mesh shrinkage. Three-dimensional mesh constructions relate to the lowest shrinkage behavior caused by higher structure stability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.