Abstract

PurposeTo analyze the dosimetric and toxicity outcomes of patients treated with postoperative stereotactic partial breast irradiation (S-PBI). MethodsWe identified 799 women who underwent S-PBI at our institution between January 2016 and December 2022. The most commonly used dose-fraction and technique were 30 Gy in 5 fractions (91.7 %) and a robotic stereotactic radiation system with real-time tracking (83.7 %). The primary endpoints were dosimetric parameters and radiation-related toxicities. For comparison, a control group undergoing ultra-hypofractionated whole breast irradiation (UF-WBI, n = 468) at the same institution was selected. ResultsA total of 815 breasts from 799 patients, with a median planning target volume (PTV) volume of 89.6 cm3, were treated with S-PBI. Treatment plans showed that the mean and maximum doses received by the PTV were 96.2 % and 104.8 % of the prescription dose, respectively. The volume of the ipsilateral breast that received 50 % of the prescription dose was 32.3 ± 8.9 %. The mean doses for the ipsilateral lung and heart were 2.5 ± 0.9 Gy and 0.65 ± 0.39 Gy, respectively. Acute toxicity occurred in 175 patients (21.5 %), predominantly of grade 1. Overall rate of late toxicity was 4 % with a median follow-up of 31.6 months. Compared to the UF-WBI group, the S-PBI group had comparably low acute toxicity (21.5 % vs. 25.2 %, p = 0.12) but significantly lower dosimetric parameters for all organs-at-risks (all p < 0.05). ConclusionIn this large cohort, S-PBI demonstrated favorable dosimetric and toxicity profiles. Considering the reduced radiation exposure to surrounding tissues, external beam PBI with advanced techniques should at least be considered over traditional WBI-based approaches for PBI candidates.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call