Abstract

A 63-yr-old woman was anaesthetized for sub-total thyroidectomy. The thyroid gland was large, deviating the trachea to the right and causing 30% tracheal narrowing at the level of the suprasternal notch. Mask ventilation was easy but laryngoscopy was Cormack and Lehane grade 3. Despite being able to see the tip of the epiglottis, tracheal intubation was impossible. An intubating laryngeal mask was inserted and although the airway was clear and ventilation easy, it was not possible to intubate the trachea either blindly or with the fibreoptic bronchoscope. Tracheal intubation was eventually achieved using a 6.5-mm cuffed oral tracheal tube via a size 4 laryngeal mask under fibreoptic control. We describe the case in detail and discuss the use of the intubating laryngeal mask, its potential limitations and how to optimize its use in similar circumstances.