Abstract

The use of large diameter metal bearing total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) increased in popularity in the last decade. More recent literature has highlighted the effect of head size in patient outcomes. Data was obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOA-NJRR) to evaluate the Birmingham (MoM) bearing surface when used with THA and HRA. There is no difference in the overall rate of revision between the THA and HRA but head size has a significant effect on revision rate. The data show that small diameter metal bearings in HRA (below 50mm) have a higher rate of revision than large diameter metal bearings in HRA (equal to and above 50mm) (P<.001). Conversely the large diameter metal bearings in THA have a higher rate of revision than the small diameter metal bearings in THA (P=.027). The revision rate for large diameter HRA compared to small diameter THA is not significantly different P=.670. We recommend caution when choosing either a large diameter (≥50mm) metal on metal THA or small diameter (<50mm) HRA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.