Abstract
Large deformation of enucleated pig eyeballs under rigid cylindrical indenters was studied analytically and experimentally. The analytic model for the eyeball consists of a fluid-filled spherical membrane composed of an incompressible, elastic material with an exponential strain energy function. The Rayleigh-Ritz technique provided an approximate solution via a potential energy formulation. Comparison with results from tests on eyeballs and a water-filled rubber (Mooney-Rivlin) shell shows good agreement at large deflection, where membrane action dominates. Due to the highly nonlinear stress-strain relations for the sclera, the load remains relatively small until the indenter displacement approaches 40-60 percent of the eyeball radius, and then the load increases rapidly. Depending on the indenter size, either a perforation or a rupture type of failure occurs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.