Abstract

A training technique for posterior truncal vagotomy and an anterior seromyotomy in the anesthetized pig is described. The first of five procedures was performed open in a conventional method. All succeeding procedures were performed after the establishment of a pneumoperitoneum with CO2 insufflation and the placement of two 10 mm trocars and three 5-mm trocars. A 45 degree camera and monopolar electrocautery were used during the video laparoscopic procedure. After completion of the procedure, the pigs were opened to closely inspect the surgery performed. Though there are some minor anatomic differences between porcine and human anatomy, the pig is an excellent model for gaining technical experience in the performance of a posterior truncal vagotomy and anterior seromyotomy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.