Abstract

BackgroundTumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver.MethodsPatients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard of care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered 1 day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard.ResultsTwenty-two patients suspected of having hepatocellular carcinoma (n = 4), cholangiocarcinoma (n = 2) or liver metastases from colorectal carcinoma (n = 12), uveal melanoma (n = 2), and breast cancer (n = 2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80 % (CT), 84 % (MRI), 62 % (inspection), 86 % (LUS), and 92 % (FI), respectively. Three metastases (12 %) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100 % sensitivity).ConclusionThis study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance.

Highlights

  • Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery

  • Twenty-two patients planned to undergo laparoscopic staging (n = 4) or resection (n = 19) of one or multiple tumors confined to the liver were included from April 2013 to November 2015

  • The present study describes the largest series of intraoperative fluorescence imaging during minimally invasive oncological liver surgery

Read more

Summary

Objectives

The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver. The purpose of the present study was to compare sensitivity and positive predictive values of fluorescence imaging with CT, MRI, visual inspection, and LUS during laparoscopic resection of several tumor types in the liver

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call