Abstract
Structural damage causes immense monetary loss and even loss of life. Therefore, there is need of a system which continuously monitors for damages in structure and warn about the presence of damages before the catastrophic failure. This can be achieved by Structural Health Monitoring (SHM) techniques. The present work focuses on localization of damage in an aluminium plate using minimum number of transducers. Experimental study is carried out on a specimen plate without damage and specimen plate having damage, and signals are collected at various locations of sensors using piezoelectric wafer transducers (PWT). Three PWTs, arranged in triangular as well as in liner fashion. Data obtained from three sensors are processed with the help of wavelet transform for calculation of time of fight and damage is located with a fair accuracy with both the arrangements of the transducers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.