Abstract
Summary One of the most common methods used to reduce excessive water production is water shutoff operations. These types of operations include injection of gel for flow profile modification. The most widely used gels are polyacrylamide- and silicate-based gels. As a way to improve and optimize gel characteristics, nanosilica can be added to the gelant solution. In this paper, laboratory testing of nanosilica-reinforced silicate and polyacrylamide gels is presented. Bulk gelation and capillary tubing tests were used for determination of gelation time, and core flooding tests on low permeability carbonate core samples were conducted as a way to assess gel-plugging ability. Tests showed that gelation time for both types of gels was faster when nanosilica was added. The strength of the polyacrylamide-based gel was enhanced. Silicate gel samples with nanosilica led to a 17% higher reduction in permeability compared to pure silicate gel, and polyacrylamide gel with the addition of nanosilica has almost 43% higher permeability reduction compared to pure polyacrylamide gel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.