Abstract This paper attempts to establish the effects, if any, of wellbore inclination on the performance of downhole gas separators. Different downhole gas separator designs have been extensively studied in the laboratory and far reaching conclusions have been drawn from observations made in the laboratory for vertical wellbores. However, it is pertinent to note that most wellbores are not truly vertical and a survey which shows the deviation of the wellbore from a vertical reference point is often present in most wellbore configurations. Hence, this paper compares the performance of different downhole gas separator designs in a vertical wellbore set up with that of the same downhole gas separators operating under similar conditions but installed in an inclined wellbore set up. Technology has made it possible to drill horizontal wells which are fast becoming ubiquitous in most oilfields. With gravity forces dominating separation in static downhole gas separators; it is certainly logical to study the effect of wellbore inclination on the separation efficiency of downhole gas separators as transport properties of multi-phase fluids are affected by gravity. With the above mentioned arguments, it becomes imperative to study downhole gas separators under conditions which best simulate oilfield operations. The approach utilizes an instrumented full scale model of an inclined well-bore and separator constructed with clear acrylic pipe. The base case consists of the entire wellbore and separator set up installed vertically and subsequent experiments were performed with the wellbore inclination angle at 45°. An air and water mixture is injected through the well's perforations. The air and water flow rate measurements define a performance plot of each separator design with respect to wellbore inclination. Continuous flow conditions were applied in all tests Results obtained from laboratory annular bubble rise experiments show that in an inclined set up, the bubbles tend to move along the walls of tubing where the effect of drag is maximum. Results from the annular bubble rise experiments in an inclined wellbore equally show that the upwards motion of the smaller bubbles tend to be considerably reduced and sometimes halted by drag while on the contrary, the larger bubble (Taylor type bubbles) have higher mobility along the walls of the tubing. Also, results from the downhole gas separator performance tests conducted in a wellbore inclined at 45° indicate that at similar operating conditions, a gravity driven downhole gas separator installed in a wellbore inclined at 45° would perform better than the same gravity driven downhole gas separator in a vertical wellbore. While at similar operating conditions, a centrifugal force driven downhole gas separator installed in a vertical wellbore would perform better than the same centrifugal force driven downhole gas separator in a wellbore inclined at 45°.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.