Abstract

Objectives: The aim of this study was to evaluate the shear bond strength of three different types of bonding systems for orthodontic brackets to tooth surface. Materials and Methods: Sixty sound premolar teeth divided randomly into three groups of 20 each. In group A, the brackets were bonded using conventional etch system. In group B, brackets were bonded using self-etch primer system, while in group C, brackets were bonded using one step adhesive system. Premolar teeth were mounted with cold acrylic resin in metallic mold and brackets were shear tested to failure using universal testing machine recorded in Newton for all specimens. Results: Group C shows significantly higher value of shear bond strength in comparison to groups A and B, while there was no significant difference between group A and B. Conclusion: Orthodontic brackets bonded to enamel surface using one-step bonding system (GC ortho connect) without primer was significantly higher than brackets bonded using conventional or self-etch systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.