Abstract
A novel sandwich-type electrochemical immunosensor for the detection of the liver cancer marker alpha-fetoprotein (AFP) in human serum is proposed. The two-dimensional MXene material Ti3C2Tx was first prepared using etching and ultrasonic stripping, and then Ti3C2Tx was used to reduce chloroauric acid to form Ti3C2Tx/AuNP composites which were modified on the surface of the glassy carbon electrodes to form probe-type sensors. The Ti3C2Tx/AuNPs provide a large number of binding sites for the AFP capture antibody (Ab1) and increase the electrochemical reaction active site. The Ti3C2Tx/copper metal-organic frameworks HKUST-1 composite was also prepared by solvothermal method and combined with toluidine blue (TB) and AFP detection antibody (Ab2) to form a labeled sandwich-type electrochemical immunosensor. The sensor achieved trace detection of AFP from 0.1 to 100ng/mL with a detection limit of 0.073pg/mL and possesses good selectivity, stability, and reproducibility. The sensor performs well in clinical samples and has good potential for clinical applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.