Abstract
Implementing an aerobic digestion step after anaerobic digestion, referred to as "post aerobic digestion" (PAD), can remove ammonia without the need for an external carbon source and destroy volatile solids. While this process has been documented at the lab-scale and full-scale, the mechanism for N removal and the corresponding microbial community that carries out this process have not been established. This research gap is important to fill because the nitrogen removal pathway has implications on aeration requirements and carbon demand, that is, short-cut N-removal requires less oxygen and carbon than simultaneous nitrification-denitrification. The aims of this research were to (i) determine if nitrite (NO2 - ) or nitrate (NO3 - ) dominates following ammonia removal and (ii) characterize the microbial community from PAD reactors. Here, lab-scale PAD reactors were seeded with biomass from two different full-scale PAD reactors. The lab-scale reactors were fed with biomass from full-scale reactors and operated in batch mode to quantify nitrogen species concentrations (ammonia, NH4 + , NO2 - , and NO3 - ) over time. Experimental results revealed that NO2 - production rates were several orders of magnitude greater than NO3 - production rates. Indeed, nitrite accumulation rate (NAR) was greater than 90% at most temperatures, confirming that shortcut nitrogen removal was the dominant NH4 + removal mechanism in PAD. Microbial community analysis via 16S rRNA sequencing indicated that ammonia oxidizing bacteria (AOB) were much more abundant than nitrite oxidizing bacteria (NOB). Overall, this study suggests that aeration requirements for post-aerobic digestion should be based on NO2 - shunt and not complete simultaneous nitrification denitrification. PRACTITIONER POINTS: AOB are a key feature of PAD microbial communities NOB are present, but in much lower abundance than AOB High nitrite accumulation ratio suggests shortcut nitrite as the main mechanism for nitrogen removal Nitritation in PAD reactors is sustained at temperatures as high as 40°C No ammonia oxidation occurred at 50°C implying different mechanisms of nitrogen removal including ammonia stripping.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.