Abstract
A new system has been designed to provide protection switching capability for the L5 repeatered line. This line-protection switching system, called lpss−3, provides one standby line for protection of as many as 10 service carrying lines. Switching equipment is located in terminal, terminal main, and switching power-feed stations. Economic and reliability considerations allow switching spans of up to 150 miles. Either temperature pilot deviations or excessive total signal energy initiates automatic switching. Manual control of all switching functions is provided locally and via telemetry. A dedicated pcm signaling system maintains interstation switching system coordination. Identical information is transmitted in complem entary form over two adjacent L5 channels. Parity and complementary checking as well as automatic retransmission of failed codes enhances error immunity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.