Abstract
The KVV radiative Auger region in the K X-ray emission spectrum of silicon in metallic powder form has been ionometrically recorded and compared with the expected spectrum calculated by using the measured L 2,3VV Auger spectrum available in the literature. It is found that the experimental KVV radiative Auger spectrum has some additional features. An attempt has been made to identify these as being due to various VV levels as final states.