Abstract

The aim of this study was to assess quantitatively the Kupffer-phase enhancement patterns of hepatic hemangiomas in contrast-enhanced ultrasound (CEUS) with Sonazoid. A total of 46 patients with 46 hepatic hemangiomas (17.1 ± 6.2 mm in diameter, 34 typical type and 12 high-flow type) underwent CEUS in the Kupffer phase. The lesion-to-liver contrast ratio in the Kupffer phase was quantitatively assessed for both types of hemangioma. Most of the hepatic hemangiomas, whether or not they were the high-flow type, were iso- to hypo-echoic relative to the surrounding liver parenchyma. The contrast ratio was –5.33 ± 6.70 dB for the high-flow hemangiomas and −4.54 ± 6.28 dB for the typical hemangiomas. There was no significant difference in contrast ratio between the two types of lesions (p = 0.73). All of the hemangiomas, whether of typical or high-flow type, are iso- to hypo-echoic relative to the surrounding liver parenchyma on Kupffer-phase imaging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.