Abstract
To identify whether capillary blood glucose measurement at an alternate site (knee) is equivalent to and less painful than capillary blood glucose measured by finger pricking. A randomized crossover trial was performed to compare capillary blood glucose measurements, pain, and preference between puncture sites (finger vs. skin fold of the knee) among 45 children with type 1 diabetes. A standard glucometer was used, and measurements were performed in both a fasting and postprandial state. In the comparison of capillary blood glucose measurements of the knee vs. the finger, we observed a non-significant difference of 5.95 ± 8.19 % and 1.32 ± 26.45 % in the fasting and postprandial states, respectively. Knee puncture was significantly less painful than finger pricking (P < 0.001). Capillary blood glucose levels measured by knee skin pricking are non-significantly lower than those measured by traditional finger pricking. Knee skin pricking is significantly less painful than finger pricking.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Diabetes in Developing Countries
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.