Abstract

AbstractThe differential scanning calorimeter (Perkin‐Elmer DSC‐1) is used to characterize the cure of a general‐purpose polyester during isothermal and scanning experiments. The technique is based on a new proposed model for the kinetics of isothermal cure. The model yields results which are in good agreement with experimental isothermal rate of reaction and integral heat of reaction data. It also gives some information about the residual reactivity of the sample after an isothermal cure experiment. With the aid of the proposed kinetic model, it is possible to obtain integral heats of reaction and rates of heat generation at different temperatures during a scanning experiment. The difference between the rate of heat input to the sample and the heat of reaction at any instant during scanning may be used to calculate the specific heat of the sample at the same instant. Specific heat data show two maxima during each scanning experiment. These maxima may be associated with transitions occurring during cure in the melt and rubbery states.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call