Abstract

Kinetic modelling of a sulfur recovery unit based on straight through sour natural gas was performed by numerical programming and the model outlet results were compared with industrial data. A recovery of 97.4mole% sulfur was observed from this unit.It was revealed that kinetic model precisely predicted the outlet results of sulfur, H2S, SO2 and CO2 with 4% absolute relative deviation in combustion furnace and 2% in catalytic convertors. The equilibrium model has shown 3% deviation for prediction of H2S/SO2 ratio from the furnace, whereas the kinetic model has shown only 0.2% deviations from the real results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.