Abstract

High-performance liquid chromatography of FK506, a macrolide immunosuppressant, was performed on a reversed-phase column. The peak was broad with the column kept at room temperature, which was accounted for by slow interconversion between the two forms of FK506. With the use of a heated column, a sharp peak was observed because of the rapid interconversion at high temperature. When the column was cooled to 0 degree C, two sharp peaks were observed because essentially no interconversion occurred at 0 degree C during elution. Analysis of the chromatograms obtained at various eluant flow rates indicated that the conversion of the two forms follows first-order kinetics, and the apparent activation energies for the conversions were calculated. The interconvertibility between the two molecular forms may be related to the immunosuppressive activity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.