Continuum robots offer many advantages for use in miniature diagnostic and interventional surgical devices. However, the creation of snake-like devices with extremely high slenderness ratios, those with great length and small diameter, remains challenging from a device design perspective. To facilitate improved slenderness ratios, high total accumulated bending angles, and high stiffness and mechanical stability of the active section, we propose the use of a flexible screw-driven mechanism to generate large distal actuation forces while still locating motors and other bulky system components at the base of the device. In comparison to tendon-based designs and push-pull rods, the design avoids the capstan-like buildup of friction. In this work, we present design, fabrication, kinestatic modeling, and experimental validation for a two-degree-of freedom, screw-based, multi-backbone continuum robot. The model that compensates the friction in the system most accurately predicts the behavior of the robot and eliminates most of the hysteresis in the input-output behavior.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.