Abstract

ABSTRACTThere is an increasing interest in modelling and control of integrated urban wastewater systems (UWS). Nevertheless, given the multiple interactions between the sub-systems – catchment, sewer system, wastewater treatment plant (WWTP) and receiving water system – the selection of effective control handles for improving receiving water quality is a major challenge. In this paper, a systematic study to identify the most important control handles in an UWS is presented. The Benchmark Simulation Model for Urban Wastewater Systems (BSM-UWS) is selected as a virtual case-study. Morris screening is used to perform global sensitivity analysis. Results indicate that, for the BSM-UWS layout, while river dissolved oxygen quality (Texc,DO) is influenced by multiple control handles both in the sewer system and WWTP, river un-ionized ammonia quality (Texc,NH3) is mainly influenced by WWTP control handles. The study highlights the need to perform simulations for at least 1 year when determining key control handles for UWS.