Abstract

Kermas for various substances averaged over the energy spectra of fast neutron therapy beams, as well as ratios of average kermas relative to muscle, were calculated in an attempt to estimate the uncertainties introduced in these quantities by the poor knowledge of the elemental kerma functions, actual neutron energy spectra, and composition of tissues and other materials. Average kermas have uncertainties of the order of 7%-25%, while for ratios of average kermas the uncertainties are of the order of 2%-5% for materials of clinical interest. It is concluded that the ratio of average kerma of muscle to A-150 tissue-equivalent plastic should be 0.93 +/- 0.03 for the new p + Be clinical neutron beams.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.