Abstract

An alternative low and high ammonium influent regime was proposed and adopted to keep a completely autotrophic nitrogen removal over nitrite (CANON) effective when treating low ammonium wastewater. Results show that, by cyclic operating at an alternative low and high ammonium concentration for 10 days and 28 days, the CANON system could effectively treat low ammonium wastewater. Excessive proliferation of nitrite oxidizing bacteria (NOB) under low ammonium environment was still the challenge for the stable CANON operation; but with 28 days of a high ammonium treatment combined with a sludge retention time control, the NOB overproliferated in the low ammonium operational period could be under control. Specifically, when the nitrite oxidation rate reached 8 g N/m3/h, the CANON system should enter the high ammonium influent operating mode. 16S rDNA high-throughput sequencing results show that the appropriate sludge discharging provided an environment favoring Candidatus Jettenia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.