Abstract

The research aim was to analyze the effect of the wastevalve mass and the deliver head on the hydram pump efficiency. The method used is the experimental method for the 3-inch hydram pump specimen, then analyzed using mathematical equations in the theory of the hydram pump on the head loss and pump efficiency. The data measured are the inflow, wastewater, and hydram pump outflow. The independent variables in this study were the wastevalve mass, namely 1.5 kg, 2.0 kg, 2.5 kg, and 3.0 kg, and deliver head, namely 3 m, 5 m, and 7 m. The results showed that the wastevalve mass and deliver head an effect on the hydram pump efficiency. The highest efficiency of the hydram pump is at a deliver head of 5 m with 1.5 kg of wastevalve mass, which is 60.60%. Meanwhile, the lowest hydram pump efficiency occurs at a deliver head of 7 m with 3.0 kg of wastevalve mass, which is 27.10%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.