Abstract

The Government of Indonesia has recently made regulation about Rusun/Rusunawa in great quantities with less time for construction. The solution is using straightforward construction for Rusun/Rusunawa. The alternative to these problems is precast construction. The method of loading test is referred to ASTM C78. Having research precast beam with mixing material grouting between nonshrinkage material by Sika 215 product and coarse aggregate with ratio 50%, 40% and 30% of percentage coarse aggregate by Sika Grout 215 weight. The result achieved, (a) deflection of conventional beam K1 2,8 mm achieve at load 7,2 ton (b) deflection of conventional beam K2 2,8 mm achieve at load 8,3 ton (c)deflection of precast beam P1 2,8 mm achieve at load 2,7 ton (d)deflection of precast beam P2 2,8 mm achieve at load 3,4 ton.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.