Abstract
The K X-ray fluorescence (XRF) parameters, which are fluorescence cross-section, vacancy transfer probabilities and fluorescence yield, of some fourth-period elements were investigated in an external magnetic field (8000 Gauss). In order to determine the fluorescence parameters, the samples were irritated with 59.54 keV gamma rays from a 241-Americium radioactive source and the rays emitted from the samples were counted in a system consisting of a silicon – lithium drifted detector, multichannel analyzer, magnetic field implementer, and a suitable computer program. The results were studied theoretically and experimentally using the data that were obtained. It was determined that the experimental results were compatible with the theoretical results for measurements without a magnetic field and K XRF parameters changed with the magnetic field.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.