Abstract

This report describes tests performed by Pacific Northwest National Laboratory (PNNL) for Numatec Hanford Corporation (NHC) as part of the overall activities for the development of the K Basin Sludge Treatment System. These tests were conducted to examine the dissolution behavior of a K East Basin canister sludge composite in nitric acid at the following concentrations: 2 M, 4 M, 6 M, 7.8 M and 10 M and temperatures of 25 C and boiling. Assuming that the sludge was 100% uranium metal, a 4X stoichiometric excess of nitric acid was used for all testing, except that conducted at 4 M. In the 4 M nitric acid dissolution test, 50% excess nitric acid was used resulting in a dissolver solution with a significantly higher solids loading. The boiling tests were conducted for 11 hr, the 25 C dissolution tests were conducted from 24 hr to 2 weeks. For the 25 C dissolution testing, the weight percent residual solids was determined, however, chemical and radiochemical analyses were not performed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.