Abstract

Jules Horowitz Reactor (JHR) irradiation test devices (so called ADELINE and MADISON) must undergo a periodic inspection every 40 months (French ESP(N) Regulation). The first step of inspection proposal was performed from October 2019 to March 2020 and concerns application of non-destructive methods for electron beam welds, while examining the possible methods and locations that could be utilized. This study has been performed in collaboration between VTT Technical Research Centre of Finland Ltd and French CEA with VTT employee secondment at CEA Cadarache. The initial conclusions of this work are the following: • Two inspection methods are likely needed. • Eddy current is likely suitable for surface examination while volumetric ultrasonic inspection can be used for tube bodies. • Inspection under-water in a storage pool (EPI) is likely the best option for location in the JHR. • Some automation and remote controls will be needed during the inspection process. The inspection area is quite large as the whole tube bodies will be inspected. • Internal surfaces located between the nested tubes likely cannot be inspected for corrosion and therefore, sealing the space from oxygen and water will be likely be the best option. • Experimental reference is a critical next step of the work to assess and qualify the inspection methods. As the next step, CEA will continue discussions on requirements of the mock-ups: for eddy current inspection, a Zircaloy-4 planar specimen with artificial reflectors is needed. For ultrasonic reference, a representative mock-up of the cylinder with a weld and artificial defect(s) is needed. The mock-up testing will provide an experimental reference to CIVA calculations as simulations of this work have been performed with CIVA software, which is extensively used in the industry and research organizations in simulation of non-destructive control. This study will allow further steps in the future, up to the qualification of inspection methods for JHR test devices.

Highlights

  • Jules Horowitz Reactor (JHR) irradiation test devices must undergo a periodic inspection every 40 months (French ESP(N) Regulation)

  • Eddy current is likely suitable for surface examination while volumetric ultrasonic inspection can be used for tube bodies

  • The mock-up testing will provide an experimental reference to CIVA calculations as simulations of this work have been performed with CIVA software, which is extensively used in the industry and research organizations in simulation of nondestructive control

Read more

Summary

INTRODUCTION

JHR irradiation test devices (so called ADELINE and MADISON) must undergo a periodic inspection every 40 months (French ESP(N) Regulation). The first step of inspection proposal concerns application of non-destructive methods for electron beam welds while examining the possible methods and locations that could be utilized. This initial study has been performed in collaboration between VTT Technical Research Centre of Finland Ltd and CEA. It was performed as VTT employee secondment at CEA Cadarache. Up to the qualification of inspection methods for JHR test devices, will include tests and simulations with CIVA software [1], which is extensively used in the industry and research organizations in simulation of nondestructive control

JHR TEST DEVICES
Possible methods
Inspection location and execution
Ultrasonic simulations
PROCEEDING TO MOCKUP TESTING
CONCLUSIONS
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.