Abstract
Jugular venous pressure (JVP) assessment is an important step in cardiovascular examination. JVP is an indirect measure of right atrial pressure / central venous pressure. The desire to measure JVP at bedside, though necessary during physical examination, is not easily achieved in most cases because of the difficulty in application of the two-ruler traditional method for its assessment. Jugulometer, a medical device designed and introduced at Ile-Ife in Nigeria for the purpose of non-invasive measurement of JVP at bedside. It is portable and easy-to-use. It consists of two bars (horizontal and vertical). The horizontal bar is embedded with spirit level while the vertical bar is graduated in centimetre. The two bars are assembled perpendicular to each other with a special mechanism which enable the vertical bar to slide over the horizontal bar without disrupting their perpendicular relationship. Jugulometer simplifies non-invasive measurement of JVP and makes the procedure more reproducible at bedside. This article is a documentation of the description, history of evolution of jugulometer and its uses in cardiovascular medicine and education. In conclusion, jugulometer is a medical device introduced at Ile-Ife in Nigeria to advance the traditional method and skill of non-invasive bedside assessment of jugular venous pressure.
Highlights
Jugulometer is a medical device designed for non-invasive measurement of jugular venous pressure (JVP) at bed-side
Internal jugular vein is used for the procedure because of its easy visualization and the pressure changes within the vein reflects the phasic pressure changes within the right atrium
Non-invasive assessment of JVP is an important step in cardiovascular system examination
Summary
Jugulometer is a medical device designed for non-invasive measurement of jugular venous pressure (JVP) at bed-side. JVP is an indirect, non-invasive measure of central venous pressure/right atrial pressure. Internal jugular vein is used for the procedure because of its easy visualization and the pressure changes within the vein reflects the phasic pressure changes within the right atrium. Non-invasive assessment of JVP is an important step in cardiovascular system examination. The use of Doppler echocardiography to measure right atrial pressure has been reported but not readily available in developing countries [1,2,3]. Measurement of JVP non-invasively is limited by logistics or procedural inefficiency limiting its reproducibility [5]. Jugulometer was introduced to improve the act of bed-side assessment of JVP
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.