Abstract

AbstractThe measurement of saturation of venous blood as it drains out of brain by sampling it from the jugular bulb provides us with an estimate of cerebral oxygenation, cerebral blood flow and cerebral metabolic requirement. Arterio-jugular venous difference of the oxygen content (AVDO2) and jugular venous oxygen saturation (SjVO2) values per se helps clinicians in identifying the impairment of cerebral oxygenation due to various factors thereby prompting implementation of corrective measures and the prevention of secondary injury to the brain due to ischaemia. SjVO2 values are also used for prognostication of patients after traumatic brain injury and in other clinical situations. Sampling and measuring SjVO2 intermittently or continuously using fibreoptic oximetry requires the tip of the catheter to be placed in the jugular bulb, which is a relatively simple bedside procedure. In the review below we have discussed the relevant anatomy, physiology, techniques, clinical applications and pitfalls of performing jugular venous oximetry as a tool for measurement of cerebral oxygenation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.