Abstract

The joints of the LVL elements with glued-in steel rods and metal connectors are considered as semi-rigid connection and requires taking of account compliance. In this study gives an analysis of the results of tests LVL beams with a metal connector on glued-in steel rods and solid LVL beams. Model of the destruction of rods in LVL is proposed, and allows for reduction the distance between the axis of the rods and from the axis of the rod to the edges in the cross section of the beam. This proposing is based on the analysis of the carried out investigations.

Highlights

  • The joints of the LVL elements with glued-in steel rods and metal connectors are considered as semi-rigid connection and requires taking of account compliance

  • In this study gives an analysis of the results of tests LVL beams with a metal connector on glued-in steel rods and solid LVL beams

  • Также очевидным и необходимым дополнением к рассмотренному виду соединения с металлической вставкой следует выполнять с двусторонней установкой гаек относительно металлической вставки, которые обеспечат включение в работу на продавливание вклееных стержней расположенных в сжатой зоне изгибаемых элементов

Read more

Summary

Introduction

Bidakov A.M., candidate of technical sciences, docent (O.M. Beketov National University of Urban Economy in Kharkiv) Raspopov I.A., postgraduate., Strashko B.O., postgraduate (Kharkiv National University of Civil Engineering and Architecture). Узловые соединения ЛВЛ бруса на вклееных стержнях с металлическими стыковыми элементами являются полу-жесткими и требует учета податливости. Полу-жесткое соединение, шпоновый брус ЛВЛ (Ultralam – R), расстояние между стержнями, модель разрушения, двусторонняя фиксация узла.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have