Abstract

In solid-state stud welding, joining is completed within a few milliseconds by using a large discharge current and pressure. Materials with high electrical resistivity are candidates for producing higher Joule heat from the same electric discharge energy. In this study, the suitability of solid-state stud welding for joining steel studs to steel plates was examined. Steel studs were successfully joined to steel plates at charged voltages of 125–200V without distortion of the plate and tarnish marks on the back surface. The joint interface between the projection and plate was arc-shaped. The deformation behavior was notably different from that in previous reports of joining aluminum alloy studs to aluminum alloy plates or magnesium alloy plates. Observation of the joining area revealed that the projection and plate deformed and spread along the plate surface, squeezing the plate material. The projection and plate deformed more severely as the charged voltage increased. The original shape of the projection tip was partially retained in the joints formed at 125 and 150V. The amount of martensite observed near the joint interface increased with the charged voltage. The ferrite was not observed above 175V in the center, and above 150V inside and outside of the projection near the joint interface. To estimate the maximum temperature reached during joining, the microstructures of the stud and plate heated at various temperatures were compared with those of joint specimens. Because ferrite and martensite was observed near the joint interface, the maximum temperature reached during joining could be estimated by the presence or absence of the ferrite and martensite. The region where the temperature increased above the A1 point extended only about 500μm around the joint interface. Because the majority of the specimen was room temperature and removed heat rapidly from the joint interface, martensite was formed despite the air cooling after joining. The tensile fracture load increased with the charged voltage. The stud and plate were joined strongly enough for the base plate to fracture partially during the tensile test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.