Abstract

Among the objections and the troubles of buildings in Japan, the floor impact sound is one of the most serious issues. The floor impact sounds are classified in a heavy- and a light-weight floor impact sound by the characteristic of the impact source. One is the floor impact sound caused by human jumping, running, or walking and the other is the floor impact sound caused by falling lightweight object. The measurement and rating method for floor impact sound insulation is standardized in JIS (Japanese Industrial Standard). JIS A 1418-2 is method using standard heavy/soft impact sources, a car-tire source (a bang machine) and a rubber ball source. The heavy-weight floor impact sound insulation is started in Japan. JIS A 1418-1, which is corresponded to ISO140-7, is method using standard light impact source, a tapping machine. The evaluation for the floor impact sound insulation is standardized in JIS A 1419-2 which is corresponded to ISO 717-2. This paper summarizes the trends for the floor impact sound ins...