Abstract

Efect of stress ratio on fatigue properties was investigated for Ni base super alloy 718 forging. Fatigue tests were conducted under stress ratios of R = -1, 0.01, 0.5 and under the condition fixing the maximum stress at 0.2% proof stress (6,,, =Co2 test). The internal fracture occurred in all test condition. The fracture sites of the internal fracture revealed the carbide inclusion and several facets. The fatigue limits determined at 107 cycles were below a modified Goodman line under R=0.01, although they were above under around R=0.5 and 0.7.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.