Abstract
The backward-curved centrifugal fan with rectangular casing is used to the air conditioners and the air cleaners that is required the compact and flexible design. We have pointed out that the performance of the fan is better than the fan with scroll casing at the large flow rate. But the noise characteristics of this type fan are not cleared yet. It is investigated the noise characteristics in relating to the interaction between the impeller and the rectangular casing by experiments and numerical simulation. It is pointed out that the interaction noise is lower than the fan with scroll casing. The turbulent noise is consists from the three frequency ranges that have the different noise sources. The low frequency range noise is generated from the impeller, the middle frequency range noise is generated from the casing wall and the high frequency range noise is generated from the shroud. The secondary flow near the shroud causes the large turbulence and generates the high frequency and large turbulent noise. We proposed the obstacle setting to reduce the noise level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of Mechanical Engineering Congress, Japan
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.