A synchrotron radiation X-ray micro-tomography system called SP-μCT with a spatial resolution of about 1μm has been developed in SPring-8. In this work, SP-μCT was applied to the nondestructive observation of fatigue crack propagation appearing due to thermal cyclic loading in lead-free solder joints of chip type resistor. In order to show the whole image of crack propagation process, 3D rendered images of fatigue cracks was extracted from CT images. The results show that nondestructive inspection of lead-free solder joints of chip type resistor by the micro CT system is useful in combination with three-dimensional visualization of the thermal fatigue cracks.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.