Abstract

Turbine generator in power plants is an important equipment, and requires its preventive maintenance for normal operation.For the inspection efficiency for turbine generator rotor, the application of ultrasonic testing technique for the keyway in a rotor shaft is demanded. The ultrasonic testing for the keyway in a rotor shaft detects crackings occurred diagonally for rotor axis. For this issue, the authors developed the cracking detection techniques by the phased array ultrasonic testing method using an array probe installed in the distant position from the keyway. The ultrasonic beams propagate three-dimensionally because the rotor shaft is a column. Therefore a control of the beam incident direction is difficult. Therefore the ultrasonic beam angle and the ultrasonic probe position for cracking detection were calculated based on the rotor's geometry. The authors confirmed the possibility of crackings detection in this calculated condition by the experiment using electric discharge machining slit in the specimen simulated a rotor shaft, and ensured the inspection reliability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.