Abstract
We have numerically investigated the effect of lowered T on the performance of the Coulomb blockade thermometer, which has been demostrated to yield primary thermometry in the high T limit where thermal excitations compete with the Coulomb blockade. The thermometer is formed by an array of tunnel junctions whose differentiated IV—curve is used to determine the temperature. The IV—curves were calculated by computer simulations and we have obtained corrections to the analytic high T behaviour due to the lowered temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.