Abstract

To compare image quality and diagnostic accuracy of arterial stenosis in low-dose lower-extremity CT angiography (CTA) between adaptive statistical iterative reconstruction-V (ASIR-V) and deep learning image reconstruction (DLIR) algorithms. 46 patients undergoing low-dose lower-extremity CTA were enrolled. Images were reconstructed using ASIR-V (blending factor of 50% (AV-50) and 100% (AV-100)) and DLIR (medium (DL-M), and high (DL-H)). CT values and standard deviation of the aorta, psoas, popliteal artery, popliteal and ankle muscles were measured. The edge-rise distance and edge-rise slope were calculated. The degrees of granularity and edge blurring were assessed using a 5-point scale. The stenosis degrees were measured on the four reconstructions, and their mean square errors against that of digital subtraction angiography were calculated and compared. For both ASIR-V and DLIR, higher reconstruction intensity generated lower noise and higher signal-to-noise ratio and contrast-to-noise ratio values. The standard deviation values in AV-100 images were significantly lower than other reconstructions. The two DLIR image groups had higher edge-rise slope and lower edge-rise distance (DL-M:1.79 ± 0.37 mm and DL-H:1.82 ± 0.38 mm vs AV-50:1.96 ± 0.39 mm and AV-100:2.01 ± 0.36 mm, p = 0.014) than ASIR-V images. The overall image quality of DLIR was rated higher than ASIR-V (DL-M:0.83 ± 0.61, DL-H:0.41 ± 0.62, AV-50:1.85 ± 0.60 and AV-100:2.37 ± 0.77, p < 0.001), with DL-H having the highest overall image quality score. For stenosis measurement, DL-H had the lowest mean-square-errors compared to digital subtraction angiography among all reconstruction groups. DLIR images had higher image quality ratings with lower image noise and sharper vessel walls in low-dose lower-extremity CTA, and DL-H provides the best overall image quality and highest accuracy in diagnosing artery stenoses. DLIR provides high-quality images with sharper edges compared to ASIR-V during low-dose CTA of lower extremity arteries, and DLIR (high) provides the best overall image quality and highest accuracy in diagnosing artery stenoses among all reconstruction algorithms (ASIR-V and DLIR). ASIR-V with blending factor of 100% has the strongest noise reduction ability among all reconstruction algorithms (ASIR-V and DLIR); however, it generates the most blurred images.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.