Abstract

A three stage Marx generator is implemented in this paper with pulse width 5 μs and repetitive frequency of output pulse is 66 Hz. The circuit is verified with simulation and hardware results with an input of 90 V. In the present work, the circuit is tested with resistive load. This paper discusses issues related with isolation of high voltage Marx generator and various methods of isolation. A high performance driver circuit for three stage Marx using optical fiber is implemented and the circuit is tested. It is found that the rise time of the output pulse of Marx circuit is improved by this method of pulse transmission by 40 ns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.