Abstract

Tritium Producing Burnable Absorber Rods (TPBARs) use nickel plated, zirconium tubing for gettering tritium. However, during the development phase of the getter design only protium gas was used to determine getter rate. The verification phase of getter performance (product acceptance testing) also used only protium gas. Thus, isotope mass effects on getter rate were not evaluated. A modified getter rate test using both protium and deuterium gas was performed to determine isotope mass effects. Test procedures were developed to measure isotope effect on getter rate versus temperature while minimizing experimental uncertainties with respect to surface cleanliness and variability of test results between different specimens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.